Uniform Building Code |
From inside the book
Results 1-3 of 34
Page 97
International Conference of Building Officials. Part IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES Chapter 16 RESTRICTIONS IN FIRE ZONES General Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this Code , the en- tire city is ...
International Conference of Building Officials. Part IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES Chapter 16 RESTRICTIONS IN FIRE ZONES General Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this Code , the en- tire city is ...
Page 98
... Fire Zone No. 1 provided any exterior wall located less than 20 feet from a property line is protected in accordance with Table No. 5 - A and Section 2103 ( a ) . Roof coverings shall be fire ... Fire Zone No 1 Restrictions in Fire Zone No 2.
... Fire Zone No. 1 provided any exterior wall located less than 20 feet from a property line is protected in accordance with Table No. 5 - A and Section 2103 ( a ) . Roof coverings shall be fire ... Fire Zone No 1 Restrictions in Fire Zone No 2.
Page 119
... fire - resistive requirements shall be as specified in Chapter 17 . For requirements due to occupancy , see Chapters 6 to 15 , inclusive . For requirements in Fire Zones see Chapter 16 . Structural Framework Sec . 2002. Structural ...
... fire - resistive requirements shall be as specified in Chapter 17 . For requirements due to occupancy , see Chapters 6 to 15 , inclusive . For requirements in Fire Zones see Chapter 16 . Structural Framework Sec . 2002. Structural ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood