Uniform Building Code |
From inside the book
Results 1-3 of 88
Page 74
International Conference of Building Officials. Chapter 10 REQUIREMENTS FOR GROUP H OCCUPANCIES Group H Occupancies Defined Sec . 1001. Group H Occupancies shall be : Division 1. Storage and handling of hazardous and highly flammable or ...
International Conference of Building Officials. Chapter 10 REQUIREMENTS FOR GROUP H OCCUPANCIES Group H Occupancies Defined Sec . 1001. Group H Occupancies shall be : Division 1. Storage and handling of hazardous and highly flammable or ...
Page 79
... Group B , Divisions 1 , 2 and 3 Occupancies Defined Sec . 1101. Group B , Divisions 1 , 2 and 3 Occupancies shall be : Division 1. Gasoline service stations , storage garages where no repair work is done except exchange of parts and ...
... Group B , Divisions 1 , 2 and 3 Occupancies Defined Sec . 1101. Group B , Divisions 1 , 2 and 3 Occupancies shall be : Division 1. Gasoline service stations , storage garages where no repair work is done except exchange of parts and ...
Page 511
... Group A , Division 1 Occupancies Sec . 3315. ( a ) Main Exit . Every Group A , Division 1 Occupancy shall be provided with a main exit . The main exit shall be of sufficient width to accommodate one - half of the total occupant load but ...
... Group A , Division 1 Occupancies Sec . 3315. ( a ) Main Exit . Every Group A , Division 1 Occupancy shall be provided with a main exit . The main exit shall be of sufficient width to accommodate one - half of the total occupant load but ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood