Uniform building code |
From inside the book
Results 1-3 of 79
Page 154
Concrete masonry units shall be of a quality at least equal to the requirements set
forth in U.B.C. Standard No. 24-4 or No. 24-5 when used for bearing walls or
piers or when in contact with ground or exposed to the weather; or equal to the ...
Concrete masonry units shall be of a quality at least equal to the requirements set
forth in U.B.C. Standard No. 24-4 or No. 24-5 when used for bearing walls or
piers or when in contact with ground or exposed to the weather; or equal to the ...
Page 194
Plywood shall be of species Group 1, 2, 3 or 4 and shall be one of the grades
specified in U.B.C. Standard No. 25-9. Approved fire-retardant treated wood shall
be dried, following treatment, to a maximum moisture content as follows: solid ...
Plywood shall be of species Group 1, 2, 3 or 4 and shall be one of the grades
specified in U.B.C. Standard No. 25-9. Approved fire-retardant treated wood shall
be dried, following treatment, to a maximum moisture content as follows: solid ...
Page 304
The specifications shall be supplemented by requirements assuring satisfactory
weldability by this procedure in conformity with U.B.C. Standard No. 26-8. The
supplementary specification requirements shall be designated in the order, and ...
The specifications shall be supplemented by requirements assuring satisfactory
weldability by this procedure in conformity with U.B.C. Standard No. 26-8. The
supplementary specification requirements shall be designated in the order, and ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength