Uniform Building Code |
From inside the book
Results 1-3 of 77
Page 54
FIRE ZONE GROUP FIRE RESISTANCE OF EXTERIOR WALLS OPENINGS IN
EXTERIOR WALLS DESCRIPTION OF OCCUPANCY 1 - Any assembly building
with a stage and an occupant load of 1000 or more in the building .
FIRE ZONE GROUP FIRE RESISTANCE OF EXTERIOR WALLS OPENINGS IN
EXTERIOR WALLS DESCRIPTION OF OCCUPANCY 1 - Any assembly building
with a stage and an occupant load of 1000 or more in the building .
Page 65
Any building or portion of a building having an assembly room with an occupant
load of less than 1000 and a stage . Division 2 . 1 . Any building or portion of a
building having an assembly room with an occupant load of 300 or more without
a ...
Any building or portion of a building having an assembly room with an occupant
load of less than 1000 and a stage . Division 2 . 1 . Any building or portion of a
building having an assembly room with an occupant load of 300 or more without
a ...
Page 691
3315 , 3316 , 3317 , 3318 , 3319 605 , 75 ASSEMBLY BUILDINGS Areas allowed
. . . . 505 , 602 , 702 Classified . . . . . . . 601 , 701 Definition Exits , special
requirements . . . Exterior walls . 603 , 703 Requirements . . . . . . . . . . . Chapters 6
, 7 ...
3315 , 3316 , 3317 , 3318 , 3319 605 , 75 ASSEMBLY BUILDINGS Areas allowed
. . . . 505 , 602 , 702 Classified . . . . . . . 601 , 701 Definition Exits , special
requirements . . . Exterior walls . 603 , 703 Requirements . . . . . . . . . . . Chapters 6
, 7 ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Permits and Inspections | 29 |
Definitions and Abbreviations | 38 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved assembly bars beam bearing bending bolts Building Official ceiling cement Chapter Code column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces frame gauge grade Grain greater Group gypsum height horizontal hour inches installed joints lateral lath least length less limited load located lumber masonry materials maximum metal nails Occupancies openings panel parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side slab solid spaced span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood Zone