Uniform Building Code |
From inside the book
Results 1-3 of 9
Page 116
... automatically if the principal supply fails . ( vii ) Operation of the sprinkler system shall activate the voice com- munication system . 2. When the automatic sprinkler system described above is installed , the following reductions ...
... automatically if the principal supply fails . ( vii ) Operation of the sprinkler system shall activate the voice com- munication system . 2. When the automatic sprinkler system described above is installed , the following reductions ...
Page 536
... sprinkler heads installed within such chutes at alternate floors . Sprinkler heads shall be accessible for ser ... automatic fire - extinguishing system as specified in U.B.C. Standards No. 48-1 and No. 48-2 . ( c ) Detailed Requirements .
... sprinkler heads installed within such chutes at alternate floors . Sprinkler heads shall be accessible for ser ... automatic fire - extinguishing system as specified in U.B.C. Standards No. 48-1 and No. 48-2 . ( c ) Detailed Requirements .
Page 636
... automatic fire - extinguishing system . EXCEPTION : Ceiling light diffusers of approved plastics shall not be re ... sprinkler heads shall be installed so that they will not interfere with the effective operation of the sprinkler system ...
... automatic fire - extinguishing system . EXCEPTION : Ceiling light diffusers of approved plastics shall not be re ... sprinkler heads shall be installed so that they will not interfere with the effective operation of the sprinkler system ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength