Page 199
... bearing in inches measured along the grain of the wood . The multiplying factors for indicated lengths of bearing on such small areas as plates and washers may be : LENGTH OF BEARING ( In inches ) 1/2 12 2 3 6 OR MORE Factor 1.75 1.38 ...
... bearing in inches measured along the grain of the wood . The multiplying factors for indicated lengths of bearing on such small areas as plates and washers may be : LENGTH OF BEARING ( In inches ) 1/2 12 2 3 6 OR MORE Factor 1.75 1.38 ...
Page 218
... bearing and for exterior wall studs and 10 feet for interior nonload - bearing studs . When used in bearing walls , Utility studs shall support not more than a roof and ceiling load . 3. Spacing . Studs supporting floors shall be spaced ...
... bearing and for exterior wall studs and 10 feet for interior nonload - bearing studs . When used in bearing walls , Utility studs shall support not more than a roof and ceiling load . 3. Spacing . Studs supporting floors shall be spaced ...
Page 440
... bearing is obtained ; rolled steel bearing plates over 2 inches but not over 4 inches in thickness may be straightened by pressing ; or , if presses are not available , by planing for all bearing surfaces ( except as noted under ...
... bearing is obtained ; rolled steel bearing plates over 2 inches but not over 4 inches in thickness may be straightened by pressing ; or , if presses are not available , by planing for all bearing surfaces ( except as noted under ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength