Page 90
... ceiling . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room is required in only one - half the area thereof . No por- tion of the room measuring less than 5 feet from the finished floor to the ...
... ceiling . If any room in a building has a sloping ceiling , the prescribed ceiling height for the room is required in only one - half the area thereof . No por- tion of the room measuring less than 5 feet from the finished floor to the ...
Page 93
... Ceiling Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to ...
... Ceiling Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to ...
Page 636
... ceiling shall be defined as any light diffusing or light transmit- ting ceiling consisting of transparent , translucent , louvered , egg - crated , mesh or similar materials suspended from a ceiling or structural framework by means of ...
... ceiling shall be defined as any light diffusing or light transmit- ting ceiling consisting of transparent , translucent , louvered , egg - crated , mesh or similar materials suspended from a ceiling or structural framework by means of ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood