Uniform Building Code |
From inside the book
Results 1-3 of 85
Page 300
... concrete to modify its properties . AGGREGATE . Inert material which is mixed with portland cement and water to produce concrete . AGGREGATE , LIGHTWEIGHT . Aggregate having a dry loose weight of 70 pounds per cubic foot or less . AIR ...
... concrete to modify its properties . AGGREGATE . Inert material which is mixed with portland cement and water to produce concrete . AGGREGATE , LIGHTWEIGHT . Aggregate having a dry loose weight of 70 pounds per cubic foot or less . AIR ...
Page 306
... Concrete 26-11 Obtaining and Testing Drilled Cores and Sawed Beams Test for Splitting Tensile Strength 26-10 26-12 READY - MIXED CONCRETE 26-13 The welding of reinforcing steel , metal inserts and connections in rein- forced concrete ...
... Concrete 26-11 Obtaining and Testing Drilled Cores and Sawed Beams Test for Splitting Tensile Strength 26-10 26-12 READY - MIXED CONCRETE 26-13 The welding of reinforcing steel , metal inserts and connections in rein- forced concrete ...
Page 310
... Concrete Sec . 2605. ( a ) Preparation of Equipment and Place of Deposit . Before concrete is placed , all equipment for mixing and transporting the concrete shall be clean , all debris and ice shall be removed from the spaces to be oc ...
... Concrete Sec . 2605. ( a ) Preparation of Equipment and Place of Deposit . Before concrete is placed , all equipment for mixing and transporting the concrete shall be clean , all debris and ice shall be removed from the spaces to be oc ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength