Page 435
For the purpose of this Section, the height of a tier structure shall be taken as the
vertical distance from the curb level to the highest point of the roof beams, in the
case of flat roofs, or to the mean height of the gable, in the case of roofs having a
...
For the purpose of this Section, the height of a tier structure shall be taken as the
vertical distance from the curb level to the highest point of the roof beams, in the
case of flat roofs, or to the mean height of the gable, in the case of roofs having a
...
Page 439
In main members carrying calculated stress the end tie plates shall have a length
of not less than the distance between the lines of rivets, bolts or welds connecting
them to the components of the member. Intermediate tie plates shall have a ...
In main members carrying calculated stress the end tie plates shall have a length
of not less than the distance between the lines of rivets, bolts or welds connecting
them to the components of the member. Intermediate tie plates shall have a ...
Page 601
Clearance above grade over 8 feet — 1 inch of projection is permitted for each
additional inch of clearance, provided that no such projection shall exceed a
distance of 4 feet. Marquees Sec. 4505. (a) General. For the purpose of this
Section a ...
Clearance above grade over 8 feet — 1 inch of projection is permitted for each
additional inch of clearance, provided that no such projection shall exceed a
distance of 4 feet. Marquees Sec. 4505. (a) General. For the purpose of this
Section a ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength