Page 48
... Fire - resistive , " " Three - hour Fire - resistive , " " Two - hour Fire - resistive , " and " One - hour Fire - resistive . " ( See U.B.C. Standard No. 43-7 for fire dampers in air ducts piercing occupancy separa- tions . ) 1. A ...
... Fire - resistive , " " Three - hour Fire - resistive , " " Two - hour Fire - resistive , " and " One - hour Fire - resistive . " ( See U.B.C. Standard No. 43-7 for fire dampers in air ducts piercing occupancy separa- tions . ) 1. A ...
Page 534
... fire - extinguishing systems required in this Code shall be installed in accordance with the requirements of this Chapter . All hose threads used in connection with fire - extinguishing systems shall comply with the standards of the Fire ...
... fire - extinguishing systems required in this Code shall be installed in accordance with the requirements of this Chapter . All hose threads used in connection with fire - extinguishing systems shall comply with the standards of the Fire ...
Page 557
... fire - resistive rating . ( g ) Glazed Openings in Fire Windows . Windows required to have a three - fourths - hour fire - resistive rating may have an area not greater than 84 square feet with neither width nor height exceeding 12 feet ...
... fire - resistive rating . ( g ) Glazed Openings in Fire Windows . Windows required to have a three - fourths - hour fire - resistive rating may have an area not greater than 84 square feet with neither width nor height exceeding 12 feet ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength