... area of such openings shall not exceed 50 percent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose ... BUILDING CODE Location on Property Allowable Floor Areas.
... area of such openings shall not exceed 50 percent of the total area of the wall in each story . ( c ) Buildings on Same Property and Buildings Containing Courts . For the purpose ... BUILDING CODE Location on Property Allowable Floor Areas.
Page 88
... area not less than one - tenth of the floor area of such rooms with a minimum of 10 square feet . All bathrooms , water closet compartments , laundry rooms and similar rooms shall be provided with natural ventilation by means of ...
... area not less than one - tenth of the floor area of such rooms with a minimum of 10 square feet . All bathrooms , water closet compartments , laundry rooms and similar rooms shall be provided with natural ventilation by means of ...
Page 90
... area thereof , but in no case shall the height of the furred ceiling be less than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room which shall have not less than 150 square feet of floor area . Other ...
... area thereof , but in no case shall the height of the furred ceiling be less than 7 feet . ( b ) Floor Area . Every dwelling unit shall have at least one room which shall have not less than 150 square feet of floor area . Other ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength