Uniform building code |
From inside the book
Results 1-3 of 57
Page 130
pounds per cubic foot and having a depth equal to that of the retained earth. Any
surcharge shall be in addition to the equivalent fluid pressure. (c) Heliport and
Helistop Landing Areas. In addition to other design requirements of this Chapter,
...
pounds per cubic foot and having a depth equal to that of the retained earth. Any
surcharge shall be in addition to the equivalent fluid pressure. (c) Heliport and
Helistop Landing Areas. In addition to other design requirements of this Chapter,
...
Page 142
'Pounds per lineal foot. 'Lateral sway bracing loads of 24 pounds per foot parallel
and 10 pounds per foot perpendicular to seat and footboards. 'All loads are in
pounds per lineal foot. Head block wells and sheave beams shall be designed
for ...
'Pounds per lineal foot. 'Lateral sway bracing loads of 24 pounds per foot parallel
and 10 pounds per foot perpendicular to seat and footboards. 'All loads are in
pounds per lineal foot. Head block wells and sheave beams shall be designed
for ...
Page 143
'A load per lineal foot to be applied horizontally at right angles to the top rail, i '
EVertical members of storage racks shall be protected from impact forces of
operating equipment or racks shall be designed so that failure of one vertical
member ...
'A load per lineal foot to be applied horizontally at right angles to the top rail, i '
EVertical members of storage racks shall be protected from impact forces of
operating equipment or racks shall be designed so that failure of one vertical
member ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength