... forces shall be multiplied by ( 1.0 / K ) to obtain the drift . The ratio ( 1.0 / K ) shall be not less than 1.0 . All portions of structures shall be designed and constructed to act as an integral unit in resisting horizontal forces ...
... forces shall be multiplied by ( 1.0 / K ) to obtain the drift . The ratio ( 1.0 / K ) shall be not less than 1.0 . All portions of structures shall be designed and constructed to act as an integral unit in resisting horizontal forces ...
Page 138
... forces . The rigidity of other elements shall be con- sidered in accordance with Section 2312 ( e ) 4 . E. Moment resisting space frames and ductile moment resisting space frames may be enclosed by or adjoined by more rigid elements ...
... forces . The rigidity of other elements shall be con- sidered in accordance with Section 2312 ( e ) 4 . E. Moment resisting space frames and ductile moment resisting space frames may be enclosed by or adjoined by more rigid elements ...
Page 139
... forces . D. Diaphragms . Floor and roof diaphragms shall be designed to resist the forces set forth in Table No. 23 - J . Diaphragms supporting concrete or masonry walls shall have continuous ties between diaphragm chords to distribute ...
... forces . D. Diaphragms . Floor and roof diaphragms shall be designed to resist the forces set forth in Table No. 23 - J . Diaphragms supporting concrete or masonry walls shall have continuous ties between diaphragm chords to distribute ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
20 feet ALLOWABLE UNIT STRESSES approved bars Building Official building or structure ceiling Code columns compression compression member compressive strength concrete conform dead load deflection diameter diaphragms Division 1 Occupancies dry or surfaced enclosure exceed Exits exterior walls EXTREME FIBER fire assembly Fire Zone Firestopping flammable liquids flexural floor area footnotes grade Group grout gypsum height joints joists lateral forces least live load location on property lumber masonry materials maximum minimum MODULUS OF ELASTICITY mortar nails nonbearing noncombustible Occupancy Separation occupant load panel Parallel to Grain partitions percent permitted plywood portion pounds per square prestressing reinforcement resisting roof rooms Selected Decking shear stress shear walls sheathing sion slab space frame span specified in Chapter specified in Section square feet square inch steel story strength studs Table tensile stress tension tests timber tion types of construction U.B.C. Standard values ventilation vertical water closet width wood