24-C. Gypsum Masonry Sec. 2406. (a) General. Gypsum masonry is that form of
construction made with gypsum block or tile in which the units are laid and set in
gypsum mortar. Gypsum masonry shall not be used in any bearing wall or where
...
24-C. Gypsum Masonry Sec. 2406. (a) General. Gypsum masonry is that form of
construction made with gypsum block or tile in which the units are laid and set in
gypsum mortar. Gypsum masonry shall not be used in any bearing wall or where
...
Page 571
2Vi - 22 22 - 22 22 2-/O 2VlE 2-/24 One 2" unit cored 2 percent maximum with Vt"
vermiculite gypsum plaster on one side One 2" unit cored 22 percent maximum
with V*" gypsum plaster on one side Vt" by No. 2 gauge vertical cold2rolled ...
2Vi - 22 22 - 22 22 2-/O 2VlE 2-/24 One 2" unit cored 2 percent maximum with Vt"
vermiculite gypsum plaster on one side One 2" unit cored 22 percent maximum
with V*" gypsum plaster on one side Vt" by No. 2 gauge vertical cold2rolled ...
Page 612
Gypsum wallboard may be applied to wood framing members with an approved
adhesive. A continuous bead of the adhesive shall be applied to the face of all
framing members, except top and bottom plates, of sufficient size as to spread to
an ...
Gypsum wallboard may be applied to wood framing members with an approved
adhesive. A continuous bead of the adhesive shall be applied to the face of all
framing members, except top and bottom plates, of sufficient size as to spread to
an ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength