Page 572
... Gypsum Plaster Wallboard 4344 59 60 34 " by No. 18 gauge steel. 214 57 58 One full - length layer 2 " Type " X " gypsum wallboard laminated to each side of 1 " full length V - edge gypsum coreboard with approved laminating compound ...
... Gypsum Plaster Wallboard 4344 59 60 34 " by No. 18 gauge steel. 214 57 58 One full - length layer 2 " Type " X " gypsum wallboard laminated to each side of 1 " full length V - edge gypsum coreboard with approved laminating compound ...
Page 611
... Gypsum Wallboard Sec . 4711. ( a ) General . All gypsum wallboard shall be installed in ac- cordance with the provisions of this Section . Gypsum wallboard shall not be installed on exterior surfaces . See Section 424. For use as ...
... Gypsum Wallboard Sec . 4711. ( a ) General . All gypsum wallboard shall be installed in ac- cordance with the provisions of this Section . Gypsum wallboard shall not be installed on exterior surfaces . See Section 424. For use as ...
Page 623
International Conference of Building Officials. THICKNESS OF GYPSUM WALLBOARD ( Inch ) SURFACE ( Center to Center ) ( In Inches ) Nails 3 PLANE OF FRAMING TABLE NO . 47 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD LONG DIMENSION OF ...
International Conference of Building Officials. THICKNESS OF GYPSUM WALLBOARD ( Inch ) SURFACE ( Center to Center ) ( In Inches ) Nails 3 PLANE OF FRAMING TABLE NO . 47 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD LONG DIMENSION OF ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength