Page 83
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than 7 feet , except that a lesser clear height may be permitted in mechanical - access open parking garages when approved by ...
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than 7 feet , except that a lesser clear height may be permitted in mechanical - access open parking garages when approved by ...
Page 93
... Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to the ...
... Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to the ...
Page 180
... height of walls . Where a wall is laterally supported top and bottom , its effective height shall be taken as the actual height of the wall . Where there is no lateral support at the top of a wall , its effective height shall be taken ...
... height of walls . Where a wall is laterally supported top and bottom , its effective height shall be taken as the actual height of the wall . Where there is no lateral support at the top of a wall , its effective height shall be taken ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength