Uniform Building Code |
From inside the book
Results 1-3 of 85
Page 83
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than 7 feet , except that a lesser clear height may be permitted in mechanical - access open parking garages when approved by ...
... height or portion thereof shall be considered as a tier . The clear height of a parking tier shall be not less than 7 feet , except that a lesser clear height may be permitted in mechanical - access open parking garages when approved by ...
Page 93
... Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to the ...
... Heights . Habitable rooms or areas shall have a ceiling height of not less than 7 feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not less than 7 feet measured to the ...
Page 180
... height of walls . Where a wall is laterally supported top and bottom , its effective height shall be taken as the actual height of the wall . Where there is no lateral support at the top of a wall , its effective height shall be taken ...
... height of walls . Where a wall is laterally supported top and bottom , its effective height shall be taken as the actual height of the wall . Where there is no lateral support at the top of a wall , its effective height shall be taken ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood