Page 217
a header, band or rim joist or to an adjoining stud or by other approved means.
Solid blocking shall be not less than 2 inches in thickness and the full depth of
joist. Notches on the ends of joists shall not exceed one-fourth the joist depth.
a header, band or rim joist or to an adjoining stud or by other approved means.
Solid blocking shall be not less than 2 inches in thickness and the full depth of
joist. Notches on the ends of joists shall not exceed one-fourth the joist depth.
Page 327
(h) Concrete Joist Floor Construction. 1 . Concrete joist construction consists of a
monolithic combination of regularly spaced ribs and a top slab arranged to span
in one direction or two orthogonal directions. 2. The joist ribs shall be at least 4 ...
(h) Concrete Joist Floor Construction. 1 . Concrete joist construction consists of a
monolithic combination of regularly spaced ribs and a top slab arranged to span
in one direction or two orthogonal directions. 2. The joist ribs shall be at least 4 ...
Page 585
Channels attached to or suspended below joists and held to bottom chord of
joists Gypsum plaster on V," perforated gypsum lath attached to V*" cold-rolled
channels, with approved clips giving continuous support to lath. Channels
attached to ...
Channels attached to or suspended below joists and held to bottom chord of
joists Gypsum plaster on V," perforated gypsum lath attached to V*" cold-rolled
channels, with approved clips giving continuous support to lath. Channels
attached to ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength