Uniform Building Code |
From inside the book
Results 1-3 of 38
Page 574
... lath . Lath attached by 4d common nails bent over or No. 14 gauge by 1 ' X 34 ' crown width staples spaced 6 on center . Plaster mixed 1 : 11⁄2 for scratch coat and 1 : 3 for brown coat , by weight , gypsum to sand aggregate 2 " x 4 ...
... lath . Lath attached by 4d common nails bent over or No. 14 gauge by 1 ' X 34 ' crown width staples spaced 6 on center . Plaster mixed 1 : 11⁄2 for scratch coat and 1 : 3 for brown coat , by weight , gypsum to sand aggregate 2 " x 4 ...
Page 616
... LATH - MAXIMUM SPACING OF SUPPORTS VERTICAL ( In inches ) Metal TYPE OF LATH2 Expanded Metal Lath ( Diamond Mesh ) MINIMUM WEIGHT ( Per Square Yard ) Solid Plaster HORIZONTAL ( In inches ) Wood or GAUGE AND MESH SIZE Wood Partitions ...
... LATH - MAXIMUM SPACING OF SUPPORTS VERTICAL ( In inches ) Metal TYPE OF LATH2 Expanded Metal Lath ( Diamond Mesh ) MINIMUM WEIGHT ( Per Square Yard ) Solid Plaster HORIZONTAL ( In inches ) Wood or GAUGE AND MESH SIZE Wood Partitions ...
Page 617
... lath , not to be used as base for gypsum plaster , without absorbent paperbacking or slot - perforated separator ... Lath ( perforated ) % " Gypsum Lath ( plain ) 1/2 " Gypsum Lath ( perforated ) 11⁄2 " Gypsum Lath ( plain ) ' For Fire ...
... lath , not to be used as base for gypsum plaster , without absorbent paperbacking or slot - perforated separator ... Lath ( perforated ) % " Gypsum Lath ( plain ) 1/2 " Gypsum Lath ( perforated ) 11⁄2 " Gypsum Lath ( plain ) ' For Fire ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength