Uniform Building Code |
From inside the book
Results 1-3 of 60
Page 128
... loads on all spans in combination with full live loads on adjacent spans and on alternate spans . EXCEPTION : Alternate span loading need not be considered where the uniform roof live load is 20 pounds per square foot or more and the ...
... loads on all spans in combination with full live loads on adjacent spans and on alternate spans . EXCEPTION : Alternate span loading need not be considered where the uniform roof live load is 20 pounds per square foot or more and the ...
Page 142
... LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See reviewing stands ...
... LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See reviewing stands ...
Page 287
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength