Page 142
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
Page 287
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
Page 393
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
20 feet ALLOWABLE UNIT STRESSES approved bars Building Official building or structure ceiling Code columns compression compression member compressive strength concrete conform dead load deflection diameter diaphragms Division 1 Occupancies dry or surfaced enclosure exceed Exits exterior walls EXTREME FIBER fire assembly Fire Zone Firestopping flammable liquids flexural floor area footnotes grade Group grout gypsum height joints joists lateral forces least live load location on property lumber masonry materials maximum minimum MODULUS OF ELASTICITY mortar nails nonbearing noncombustible Occupancy Separation occupant load panel Parallel to Grain partitions percent permitted plywood portion pounds per square prestressing reinforcement resisting roof rooms Selected Decking shear stress shear walls sheathing sion slab space frame span specified in Chapter specified in Section square feet square inch steel story strength studs Table tensile stress tension tests timber tion types of construction U.B.C. Standard values ventilation vertical water closet width wood