Uniform Building Code |
From inside the book
Results 1-3 of 85
Page 142
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
Page 287
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
Page 393
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood