Page 142
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
... LOAD LATERAL LOAD CATEGORY DESCRIPTION ( Pounds per Square Foot Unless Otherwise Noted ) 1. Construction , Walkway See Sec . public access at 4406 150 site ( live load ) Canopy See Sec . 4407 150 2. Grandstands , Seats and foot- See ...
Page 287
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
... loads . ' Uniform load deflection limitation : 1 / 180th of the span under live load plus dead load , 1 / 240th under live load only . Edges may be blocked with lumber or other approved type of edge support . ' Identification index ...
Page 393
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
... load . The portion of the structure selected for loading shall be subjected to a total load , including the dead loads already in place , equivalent to 0.85 ( 1.4D + 1.7L ) . The determination of L shall include live load reductions as ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength