Uniform Building Code |
From inside the book
Results 1-3 of 89
Page 160
... Masonry Sec . 2408. ( a ) General . Masonry of glass blocks may be used in nonload - bearing exterior or interior walls and in openings which ... masonry 160 2407-2410 UNIFORM BUILDING CODE Glass Masonry Stone Masonry Cavity Wall Masonry.
... Masonry Sec . 2408. ( a ) General . Masonry of glass blocks may be used in nonload - bearing exterior or interior walls and in openings which ... masonry 160 2407-2410 UNIFORM BUILDING CODE Glass Masonry Stone Masonry Cavity Wall Masonry.
Page 167
... Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be embedded in structural masonry when their location ...
... Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be embedded in structural masonry when their location ...
Page 176
... Masonry . Partially Sec . 2419. ( a ) Partially reinforced masonry shall be designed as unreinforced masonry , except that reinforced areas or elements may be considered as resisting stresses in accordance with the design criteria ...
... Masonry . Partially Sec . 2419. ( a ) Partially reinforced masonry shall be designed as unreinforced masonry , except that reinforced areas or elements may be considered as resisting stresses in accordance with the design criteria ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength