Uniform Building Code |
From inside the book
Results 1-3 of 89
Page 160
... Masonry Sec . 2408. ( a ) General . Masonry of glass blocks may be used in nonload - bearing exterior or interior walls and in openings which ... masonry 160 2407-2410 UNIFORM BUILDING CODE Glass Masonry Stone Masonry Cavity Wall Masonry.
... Masonry Sec . 2408. ( a ) General . Masonry of glass blocks may be used in nonload - bearing exterior or interior walls and in openings which ... masonry 160 2407-2410 UNIFORM BUILDING CODE Glass Masonry Stone Masonry Cavity Wall Masonry.
Page 167
... Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be embedded in structural masonry when their location ...
... Masonry . No pipe or conduit shall be embedded in any structural masonry necessary for structural stability or required fire protection . EXCEPTIONS : 1. Rigid electric conduits may be embedded in structural masonry when their location ...
Page 176
... Masonry . Partially Sec . 2419. ( a ) Partially reinforced masonry shall be designed as unreinforced masonry , except that reinforced areas or elements may be considered as resisting stresses in accordance with the design criteria ...
... Masonry . Partially Sec . 2419. ( a ) Partially reinforced masonry shall be designed as unreinforced masonry , except that reinforced areas or elements may be considered as resisting stresses in accordance with the design criteria ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood