Glass Masonry Sec. 2408. (a) General. Masonry of glass blocks may be used in
nonload-bearing exterior or interior walls and in openings which might otherwise
be filled with windows, either isolated or in continuous bands, provided the glass
...
Glass Masonry Sec. 2408. (a) General. Masonry of glass blocks may be used in
nonload-bearing exterior or interior walls and in openings which might otherwise
be filled with windows, either isolated or in continuous bands, provided the glass
...
Page 176
(a) Partially Reinforced Masonry. Partially reinforced masonry shall be designed
as unreinforced masonry, except that reinforced areas or elements may be
considered as resisting stresses in accordance with the design criteria specified
in ...
(a) Partially Reinforced Masonry. Partially reinforced masonry shall be designed
as unreinforced masonry, except that reinforced areas or elements may be
considered as resisting stresses in accordance with the design criteria specified
in ...
Page 189
24-J— ASSUMED COMPRESSIVE STRENGTH OF UNREINFORCED BRICK
MASONRY' 'See Section 2419(c) 1. TABLE NO. 24-K-ALLOWABLE STRESSES
IN UNREINFORCED ENGINEERED BRICK MASONRY 'See 189 1976 EDITION
...
24-J— ASSUMED COMPRESSIVE STRENGTH OF UNREINFORCED BRICK
MASONRY' 'See Section 2419(c) 1. TABLE NO. 24-K-ALLOWABLE STRESSES
IN UNREINFORCED ENGINEERED BRICK MASONRY 'See 189 1976 EDITION
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength