Uniform Building Code |
From inside the book
Results 1-3 of 78
Page 548
... materials which are less than 28 inch in thickness cemented to the surface of walls or ceilings , if these materials have flame - spread characteristics no greater than paper of this thickness cemented to a noncombustible backing . Foam ...
... materials which are less than 28 inch in thickness cemented to the surface of walls or ceilings , if these materials have flame - spread characteristics no greater than paper of this thickness cemented to a noncombustible backing . Foam ...
Page 628
... materials and establish methods of safe construction where any structure or portion thereof is wholly or partially prefabricated . ( b ) Scope . Unless otherwise specifically stated in this Chapter , all prefabricated construction and ...
... materials and establish methods of safe construction where any structure or portion thereof is wholly or partially prefabricated . ( b ) Scope . Unless otherwise specifically stated in this Chapter , all prefabricated construction and ...
Page 634
... material . ( b ) General . In Type V - N construction , doors , sash and framed open- ings , not required to be fire protected , may be glazed or equipped with ap- proved plastic materials . In all types of construction having ...
... material . ( b ) General . In Type V - N construction , doors , sash and framed open- ings , not required to be fire protected , may be glazed or equipped with ap- proved plastic materials . In all types of construction having ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength