All egress or rescue windows from sleeping rooms shall have a minimum net
clear opening of 5.7 square feet. The minimum net clear opening height
dimension shall be 24 inches. The minimum net clear opening width dimension
shall be 20 ...
All egress or rescue windows from sleeping rooms shall have a minimum net
clear opening of 5.7 square feet. The minimum net clear opening height
dimension shall be 24 inches. The minimum net clear opening width dimension
shall be 20 ...
Page 92
All egress or rescue windows from sleeping rooms shall have a minimum net
clear opening of 5.7 square feet. The minimum net clear opening height
dimension shall be 24 inches. The minimum net clear opening width dimension
shall be 20 ...
All egress or rescue windows from sleeping rooms shall have a minimum net
clear opening of 5.7 square feet. The minimum net clear opening height
dimension shall be 24 inches. The minimum net clear opening width dimension
shall be 20 ...
Page 174
The sum of the areas of horizontal and vertical reinforcement shall be at least
0.002 times the gross cross-sectional area of the wall and the minimum area of
reinforcement in either direction shall be not less than 0.0007 times the gross ...
The sum of the areas of horizontal and vertical reinforcement shall be at least
0.002 times the gross cross-sectional area of the wall and the minimum area of
reinforcement in either direction shall be not less than 0.0007 times the gross ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength