Page 576
... nails . Approved metal fastener grips used with nails at vertical butt joints along studs 48 Wallboard Each Side ( Cont'd . ) 74 Studs- Interior Partition 75 with Gypsum Each Side 76 77 2 " x 4 " wood studs 16 " on center with two ...
... nails . Approved metal fastener grips used with nails at vertical butt joints along studs 48 Wallboard Each Side ( Cont'd . ) 74 Studs- Interior Partition 75 with Gypsum Each Side 76 77 2 " x 4 " wood studs 16 " on center with two ...
Page 579
... nails 12 " on center . The face layer is placed horizontally and attached with 8d box nails 8 " on center at joints and 12 " on center elsewhere . The exterior face has a base layer of " Type " X " gypsum wallboard placed vertically ...
... nails 12 " on center . The face layer is placed horizontally and attached with 8d box nails 8 " on center at joints and 12 " on center elsewhere . The exterior face has a base layer of " Type " X " gypsum wallboard placed vertically ...
Page 623
... NAILS TO WOOD Screws4 Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Horizontal Either Direction 16 7 12 5/8 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Nail ...
... NAILS TO WOOD Screws4 Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Horizontal Either Direction 16 7 12 5/8 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Nail ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength