Uniform Building Code |
From inside the book
Results 1-3 of 85
Page 88
... openings from guest rooms to public corridors . Door openings from guest rooms to public corridors shall be protected as specified in Section 3304 . Every sleeping room below the fourth story shall have at least one operable window or ...
... openings from guest rooms to public corridors . Door openings from guest rooms to public corridors shall be protected as specified in Section 3304 . Every sleeping room below the fourth story shall have at least one operable window or ...
Page 103
... Openings . Every opening into a shaft enclosure shall be protected by a self - closing fire assembly conforming to Section 4306 and having a fire - protection rating of one hour for openings through one- hour walls and one and one ...
... Openings . Every opening into a shaft enclosure shall be protected by a self - closing fire assembly conforming to Section 4306 and having a fire - protection rating of one hour for openings through one- hour walls and one and one ...
Page 121
... Openings and Partitions Sec . 2103. ( a ) Exterior Walls . Exterior walls of Types III and IV buildings shall be ... openings are permitted and noncombustible two - hour fire - resistive where protection of openings is required . 3. In ...
... Openings and Partitions Sec . 2103. ( a ) Exterior Walls . Exterior walls of Types III and IV buildings shall be ... openings are permitted and noncombustible two - hour fire - resistive where protection of openings is required . 3. In ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood