Page 29
... Plans and Specifications . With each application for a building per- mit , and when required by the Building Official for enforcement of any provisions of this Code , two sets of plans and specifications shall be sub- mitted . The ...
... Plans and Specifications . With each application for a building per- mit , and when required by the Building Official for enforcement of any provisions of this Code , two sets of plans and specifications shall be sub- mitted . The ...
Page 30
... plans to a specific sec- tion or part of this Code or other ordinances or laws . Computations , stress diagrams , and other data sufficient to show the correctness of the plans , shall be submitted when required by the Building Official .
... plans to a specific sec- tion or part of this Code or other ordinances or laws . Computations , stress diagrams , and other data sufficient to show the correctness of the plans , shall be submitted when required by the Building Official .
Page 680
... plans or specifications . ( f ) Engineering Geology Report . The engineering geology report re- quired by subsection ( c ) shall include an adequate description of the geology of the site , conclusions and recommendations regarding the ...
... plans or specifications . ( f ) Engineering Geology Report . The engineering geology report re- quired by subsection ( c ) shall include an adequate description of the geology of the site , conclusions and recommendations regarding the ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength