No building or structure of Groups A,E,I,H,B or R, Division 1 Occupancy, shall be
used or occupied, and no change in the existing occupancy classification of a
building or structure or portion thereof shall be made until the Building Official
has ...
No building or structure of Groups A,E,I,H,B or R, Division 1 Occupancy, shall be
used or occupied, and no change in the existing occupancy classification of a
building or structure or portion thereof shall be made until the Building Official
has ...
Page 41
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof, exclusive of vent shafts and courts. The floor area of a
building, or portion thereof, not provided with surrounding exterior walls shall be
the ...
FLOOR AREA is the area included within the surrounding exterior walls of a
building or portion thereof, exclusive of vent shafts and courts. The floor area of a
building, or portion thereof, not provided with surrounding exterior walls shall be
the ...
Page 496
The occupant load permitted in any building or portion thereof shall be
determined by dividing the floor area assigned to that use by the square feet per
occupant as set forth in Table No. 33-A. When the square feet per occupant are
not given ...
The occupant load permitted in any building or portion thereof shall be
determined by dividing the floor area assigned to that use by the square feet per
occupant as set forth in Table No. 33-A. When the square feet per occupant are
not given ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength