Uniform Building Code |
From inside the book
Results 1-3 of 81
Page 54
1 and 3 , Group A 21 hour Occupancies Protected less than 10 feet 3 | 1 hour less
than 10 feet NOTES : ( 1 ) See Section 504 for type of walls affected and
requireinents covering percentage of openings permitted in exterior walls . 12 )
For ...
1 and 3 , Group A 21 hour Occupancies Protected less than 10 feet 3 | 1 hour less
than 10 feet NOTES : ( 1 ) See Section 504 for type of walls affected and
requireinents covering percentage of openings permitted in exterior walls . 12 )
For ...
Page 55
3 - Any building used for day care purposes for more than 6 children Not
permitted less than 2 hour less than 20 feet | 5 feet 1 hour elsewhere Protected
less than 20 feet 2 hour less than 10 feet Not permitted less than 1 hour
elsewhere 5 feet ...
3 - Any building used for day care purposes for more than 6 children Not
permitted less than 2 hour less than 20 feet | 5 feet 1 hour elsewhere Protected
less than 20 feet 2 hour less than 10 feet Not permitted less than 1 hour
elsewhere 5 feet ...
Page 57
Not permitted less than 5 feet Protected less than 20 feet 1 hour 1 hour less than
20 feet 1 2 hour less than 20 feet 1 hour elsewhere Not permitted less than 3 feet
Protected less than 20 feet B - 4 Ice plants , power plants , pumping plants , cold ...
Not permitted less than 5 feet Protected less than 20 feet 1 hour 1 hour less than
20 feet 1 2 hour less than 20 feet 1 hour elsewhere Not permitted less than 3 feet
Protected less than 20 feet B - 4 Ice plants , power plants , pumping plants , cold ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Permits and Inspections | 29 |
Definitions and Abbreviations | 38 |
Copyright | |
8 other sections not shown
Other editions - View all
Common terms and phrases
accordance allowable applied approved assembly bars beam bearing bending bolts Building Official ceiling cement Chapter Code column compression compressive stress computed concrete conform connections considered construction continuous covered Decking determined diameter direction distance Division doors edge effective equal exceed EXCEPTION exit exterior face factor feet fire fire-resistive flange floor foot forces frame gauge grade Grain greater Group gypsum height horizontal hour inches installed joints lateral lath least length less limited load located lumber masonry materials maximum metal nails Occupancies openings panel parallel percent permitted placed plaster plate portion pounds protected ratio reinforcement resist roof Section Select separation shear side slab solid spaced span specified square steel story strength stress Structural studs surface Table tension tests thickness tion Type U.B.C. Standard unit values vertical walls welds width wire wood Zone