... rooms to public corridors . Door openings from guest rooms to public corridors shall be protected as specified in Section 3304 . Every sleeping room below the fourth story shall have at least one operable window or exterior door ...
... rooms to public corridors . Door openings from guest rooms to public corridors shall be protected as specified in Section 3304 . Every sleeping room below the fourth story shall have at least one operable window or exterior door ...
Page 93
... rooms , dor- mitories , habitable rooms , and in public corridors . One - fifth of the air supply shall be taken ... room other than 93 1976 EDITION 1405-1407 Yards and Courts Room Dimensions.
... rooms , dor- mitories , habitable rooms , and in public corridors . One - fifth of the air supply shall be taken ... room other than 93 1976 EDITION 1405-1407 Yards and Courts Room Dimensions.
Page 513
... room or rooms is less than 10 . 2. Where the enclosures forming interior rooms are less than two - thirds of the floor to ceiling height and do not exceed 8 feet . 3. Rooms used exclusively for mechanical and public utility service to ...
... room or rooms is less than 10 . 2. Where the enclosures forming interior rooms are less than two - thirds of the floor to ceiling height and do not exceed 8 feet . 3. Rooms used exclusively for mechanical and public utility service to ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength