Uniform Building Code |
From inside the book
Results 1-3 of 78
Page 210
... spacing and loads . Plywood in shear walls shall be at least 6 inch thick for studs spaced 16 inches on center and % inch thick where studs are spaced 24 inches on center . Maximum spans for plywood subfloor underlayment shall be as set ...
... spacing and loads . Plywood in shear walls shall be at least 6 inch thick for studs spaced 16 inches on center and % inch thick where studs are spaced 24 inches on center . Maximum spans for plywood subfloor underlayment shall be as set ...
Page 219
... spaced not over 24 inches on center . C. Plywood sheathing with a thickness not less than 6 inch for 16- inch stud spacing and not less than 3⁄4 inch for 24 - inch stud spacing in accordance with Tables No. 25 - M and No. 25 - N . D ...
... spaced not over 24 inches on center . C. Plywood sheathing with a thickness not less than 6 inch for 16- inch stud spacing and not less than 3⁄4 inch for 24 - inch stud spacing in accordance with Tables No. 25 - M and No. 25 - N . D ...
Page 592
... Spaced 16 " On Center13 ( Cont'd . ) CEILING CONSTRUCTION Perlite or vermiculite gyp- sum plaster on metal lath secured to joists with 11⁄2 " by No. 11 gauge by 16 " head barbed shank roof- ing nails spaced 5 " on center 25 25 Plywood ...
... Spaced 16 " On Center13 ( Cont'd . ) CEILING CONSTRUCTION Perlite or vermiculite gyp- sum plaster on metal lath secured to joists with 11⁄2 " by No. 11 gauge by 16 " head barbed shank roof- ing nails spaced 5 " on center 25 25 Plywood ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength