Uniform building code |
From inside the book
Results 1-3 of 85
Page 52
aircraft storage hangars and as further limited in Section 1002 (b) for aircraft
repair hangars. ... The area specified in Section 505 may be tripled in one-story
buildings and doubled in buildings of more than one story if the building is
provided ...
aircraft storage hangars and as further limited in Section 1002 (b) for aircraft
repair hangars. ... The area specified in Section 505 may be tripled in one-story
buildings and doubled in buildings of more than one story if the building is
provided ...
Page 98
5-A and Section 2103 (a). Roof coverings shall be fire retardant as specified in
Section 3203 (e). See Section 104 (f) for repairs. (b) Alterations. No building of
Type II, One-hour or II-N construction in excess of 1000 square feet in floor area
nor ...
5-A and Section 2103 (a). Roof coverings shall be fire retardant as specified in
Section 3203 (e). See Section 104 (f) for repairs. (b) Alterations. No building of
Type II, One-hour or II-N construction in excess of 1000 square feet in floor area
nor ...
Page 324
7. Fire protection. Where Chapter 43 requires a fire-protective covering greater
than the concrete protection specified in this Section, such greater thicknesses
shall be used. Analysis and Design Sec. 2608. (a) Notations. (b) Design Methods
.
7. Fire protection. Where Chapter 43 requires a fire-protective covering greater
than the concrete protection specified in this Section, such greater thicknesses
shall be used. Analysis and Design Sec. 2608. (a) Notations. (b) Design Methods
.
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Effective Use of the Uniform Building Code 2021 | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
122 other sections not shown
Other editions - View all
Common terms and phrases
approved automatic fire-extinguishing systems axial bars beam bending bolts Building Official building or structure Code column compression members compressive strength computed concrete conform dead load Decking deflection diameter distance Division 1 Occupancies exceed exit exterior walls feet 1 hour feet Protected less Fire Zone flange floor area foot frame girders grout gypsum height hour less joists least length less than 20 live load longitudinal lumber masonry materials maximum minimum noncombustible O2 OO Occupancy Separation occupant load OO O2 OO OO openings panel percent permitted less plywood portion pounds per square prestressed concrete prestressing ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel studs Table tensile tensile stress tension tests thickness tion U.B.C. Standard unit stress values ventilation vertical water closet welds width wood yield strength