Uniform Building Code |
From inside the book
Results 1-3 of 88
Page 90
... feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
... feet 6 inches except as otherwise permitted in this Section . Other rooms or areas may have a ceiling height of not ... square feet of floor area . Other habitable rooms except kitchens shall have an area of not less than 70 square feet ...
Page 535
... feet from such openings , the story shall be provided with an approved automatic fire - extinguishing system , or ... square feet in area ; and in dressing rooms , workshops and storerooms accessory to such stages or enclosed platforms ...
... feet from such openings , the story shall be provided with an approved automatic fire - extinguishing system , or ... square feet in area ; and in dressing rooms , workshops and storerooms accessory to such stages or enclosed platforms ...
Page 637
... square feet . Partitions Sec . 5208. Where partitions are not required to be of fire - resistive or noncombustible construction , approved plastics conforming to the re- quirements specified in Chapter 42 and Section 1705 ( b ) 4 may be ...
... square feet . Partitions Sec . 5208. Where partitions are not required to be of fire - resistive or noncombustible construction , approved plastics conforming to the re- quirements specified in Chapter 42 and Section 1705 ( b ) 4 may be ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength