Uniform Building Code |
From inside the book
Results 1-3 of 38
Page 504
... stairways that extend to the roof with an opening onto that roof . ( n ) Stairway Construction - Exterior . Exterior stairways shall be of noncombustible material except that on Types III and IV buildings not ex- ceeding two stories in ...
... stairways that extend to the roof with an opening onto that roof . ( n ) Stairway Construction - Exterior . Exterior stairways shall be of noncombustible material except that on Types III and IV buildings not ex- ceeding two stories in ...
Page 505
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving ... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also in ...
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving ... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also in ...
Page 511
... stairway , exterior stairway or exit passageway leading to a public way . Side exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony having an occupant load of more than 10 shall be provided with a minimum ...
... stairway , exterior stairway or exit passageway leading to a public way . Side exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony having an occupant load of more than 10 shall be provided with a minimum ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength