... stairways that extend to the roof with an opening onto that roof . ( n ) Stairway Construction - Exterior . Exterior stairways shall be of noncombustible material except that on Types III and IV buildings not ex- ceeding two stories in ...
... stairways that extend to the roof with an opening onto that roof . ( n ) Stairway Construction - Exterior . Exterior stairways shall be of noncombustible material except that on Types III and IV buildings not ex- ceeding two stories in ...
Page 505
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving ... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also in ...
... stairway , ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving ... Stairway and ramp enclosures shall include landings and parts of floors connecting stairway flights and shall also in ...
Page 511
... stairway , exterior stairway or exit passageway leading to a public way . Side exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony having an occupant load of more than 10 shall be provided with a minimum ...
... stairway , exterior stairway or exit passageway leading to a public way . Side exits shall be accessible from a cross aisle . ( c ) Balcony Exits . Every balcony having an occupant load of more than 10 shall be provided with a minimum ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
20 feet ALLOWABLE UNIT STRESSES approved bars Building Official building or structure ceiling Code columns compression compression member compressive strength concrete conform dead load deflection diameter diaphragms Division 1 Occupancies dry or surfaced enclosure exceed Exits exterior walls EXTREME FIBER fire assembly Fire Zone Firestopping flammable liquids flexural floor area footnotes grade Group grout gypsum height joints joists lateral forces least live load location on property lumber masonry materials maximum minimum MODULUS OF ELASTICITY mortar nails nonbearing noncombustible Occupancy Separation occupant load panel Parallel to Grain partitions percent permitted plywood portion pounds per square prestressing reinforcement resisting roof rooms Selected Decking shear stress shear walls sheathing sion slab space frame span specified in Chapter specified in Section square feet square inch steel story strength studs Table tensile stress tension tests timber tion types of construction U.B.C. Standard values ventilation vertical water closet width wood