Uniform Building Code |
From inside the book
Results 1-3 of 77
Page 578
... surface with interior surface treatment as required for in- terior , nonbearing , noncombustible stud partitions in this Table . Plaster mix 1 : 4 for scratch coat and 1 : 5 for brown coat , by volume , cement to sand 24 " x 334 " clay ...
... surface with interior surface treatment as required for in- terior , nonbearing , noncombustible stud partitions in this Table . Plaster mix 1 : 4 for scratch coat and 1 : 5 for brown coat , by volume , cement to sand 24 " x 334 " clay ...
Page 639
... surface normally used as a walking surface , sliding glass door units , in- cluding fixed glass panels which are part of such units , shower doors , tub enclosures and storm doors shall comply with Section 5401 ( b ) . For shower doors ...
... surface normally used as a walking surface , sliding glass door units , in- cluding fixed glass panels which are part of such units , shower doors , tub enclosures and storm doors shall comply with Section 5401 ( b ) . For shower doors ...
Page 687
... surface elevations , as - graded ground surface elevations , lot drainage patterns and locations and elevations of all surface and sub- surface drainage facilities . He shall provide approval that the work was done in accordance with ...
... surface elevations , as - graded ground surface elevations , lot drainage patterns and locations and elevations of all surface and sub- surface drainage facilities . He shall provide approval that the work was done in accordance with ...
Contents
Effective Use of the Uniform Building Code | 20 |
Permits and Inspections | 29 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
88 other sections not shown
Other editions - View all
Common terms and phrases
accordance additional allowable applied approved assembly bars beam bearing bending Building Official ceiling Chapter Code columns compression concrete conform considered construction continuous covered Decking determined diameter direction distance Division effective equal equipment exceed EXCEPTION Exits exterior walls face factor feet fire Fire Zone fire-resistive floor foot forces frame grade Grain greater Group grout height horizontal hour inches increased inspection installed joints lateral least length less limited live load load located masonry materials maximum mortar nails noncombustible Occupancies one-hour openings panel Parallel partitions percent permitted placed portion protected reinforcement resisting roof rooms Select Structural separated shear sheathing side solid space span Special specified specified in Section square feet steel story strength studs Surfaced Table tension tests thickness timber tion Type U.B.C. Standard unit unit stress values ventilation vertical wide width wood