Uniform Building Code |
From inside the book
Results 1-3 of 77
Page 578
... surface with interior surface treatment as required for in- terior , nonbearing , noncombustible stud partitions in this Table . Plaster mix 1 : 4 for scratch coat and 1 : 5 for brown coat , by volume , cement to sand 24 " x 334 " clay ...
... surface with interior surface treatment as required for in- terior , nonbearing , noncombustible stud partitions in this Table . Plaster mix 1 : 4 for scratch coat and 1 : 5 for brown coat , by volume , cement to sand 24 " x 334 " clay ...
Page 639
... surface normally used as a walking surface , sliding glass door units , in- cluding fixed glass panels which are part of such units , shower doors , tub enclosures and storm doors shall comply with Section 5401 ( b ) . For shower doors ...
... surface normally used as a walking surface , sliding glass door units , in- cluding fixed glass panels which are part of such units , shower doors , tub enclosures and storm doors shall comply with Section 5401 ( b ) . For shower doors ...
Page 687
... surface elevations , as - graded ground surface elevations , lot drainage patterns and locations and elevations of all surface and sub- surface drainage facilities . He shall provide approval that the work was done in accordance with ...
... surface elevations , as - graded ground surface elevations , lot drainage patterns and locations and elevations of all surface and sub- surface drainage facilities . He shall provide approval that the work was done in accordance with ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved axial bars beam bending bolts Building Official building or structure ceiling Code column compression members compressive strength concrete conform dead load diameter diaphragms Division 1 Occupancies exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural framing gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum modulus of elasticity mortar nails noncombustible occupant load one-hour fire-resistive openings panel Parallel to Grain percent permitted perpendicular plaster plywood portland cement pounds per square prestressing protected ratio reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section splices square feet square inch steel strength studs surface Table tensile stress tension tests thickness tion Type U.B.C. Standard values vertical welds width wire wood yield strength