... wire fabric , plain or deformed , for stirrups and ties shall not be less than four wire diameters for deformed wire larger than D6 and two wire diameters for all other wires . Bends with inside diameter of less than eight wire ...
... wire fabric , plain or deformed , for stirrups and ties shall not be less than four wire diameters for deformed wire larger than D6 and two wire diameters for all other wires . Bends with inside diameter of less than eight wire ...
Page 559
... wire ties ( .08 " diameter ) at each course of tile with or without Grade A concrete fill ; 3/4 " mortar be- tween tile and column Solid gypsum blocks with woven wire mesh2 in horizontal joints , laid with 1 " mortar on flanges ' and ...
... wire ties ( .08 " diameter ) at each course of tile with or without Grade A concrete fill ; 3/4 " mortar be- tween tile and column Solid gypsum blocks with woven wire mesh2 in horizontal joints , laid with 1 " mortar on flanges ' and ...
Page 614
... ( Wire Loops at Supports ) MAXIMUM AREA SUPPORTED ( In Square Feet ) SIZE No. 9 gauge wire No. 8 gauge wire 16 " diameter , mild steel rod ' 32 " diameter , mild steel rod ' 1/4 " diameter , mild steel rod2 1 " x 6 " mild steel flats ' No ...
... ( Wire Loops at Supports ) MAXIMUM AREA SUPPORTED ( In Square Feet ) SIZE No. 9 gauge wire No. 8 gauge wire 16 " diameter , mild steel rod ' 32 " diameter , mild steel rod ' 1/4 " diameter , mild steel rod2 1 " x 6 " mild steel flats ' No ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength