International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 86
Page 81
... 12 inches . b . This table is not intended to prohibit the use of an ICF manufacturer's tables based on engineering ... ( inches ) MAXIMUM WALL HEIGHT ( feet ) MAXIMUM UNBALANCED BACKFILL HEIGHT9 ( feet ) 4 Soil group Ih # 4 @ 48 " Soil ...
... 12 inches . b . This table is not intended to prohibit the use of an ICF manufacturer's tables based on engineering ... ( inches ) MAXIMUM WALL HEIGHT ( feet ) MAXIMUM UNBALANCED BACKFILL HEIGHT9 ( feet ) 4 Soil group Ih # 4 @ 48 " Soil ...
Page 114
... ( inches ) 5/16 DESCRIPTIONa , b OF FASTENER AND LENGTH ( inches ) SPACING OF FASTENERS Edges ( inches ) Intermediate ... 12 6 12 6 12 4 6 12 202 10 12 15/32 and 1/2 0.097 - 0.099 Nail 158 Staple 16 ga . 134 12 62 0.113 Nail 17 / g 6 12 19 ...
... ( inches ) 5/16 DESCRIPTIONa , b OF FASTENER AND LENGTH ( inches ) SPACING OF FASTENERS Edges ( inches ) Intermediate ... 12 6 12 6 12 4 6 12 202 10 12 15/32 and 1/2 0.097 - 0.099 Nail 158 Staple 16 ga . 134 12 62 0.113 Nail 17 / g 6 12 19 ...
Page 172
... inches ( 102 mm ) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches ( 812 mm ) on center with one bar within 12 inches ( 305 mm ) of the top of the wall story . Concrete walls 5.5 inches ( 140 ...
... inches ( 102 mm ) shall have a minimum of one continuous No. 4 horizontal reinforc- ing bar placed at 32 inches ( 812 mm ) on center with one bar within 12 inches ( 305 mm ) of the top of the wall story . Concrete walls 5.5 inches ( 140 ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength