International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 89
Page 76
... grade adjacent to the foundation at all points a minimum of 4 inches ( 102 mm ) where masonry veneer is used and a ... grade mark of a lumber grading or inspec- tion agency which has been approved by an accreditation body that complies ...
... grade adjacent to the foundation at all points a minimum of 4 inches ( 102 mm ) where masonry veneer is used and a ... grade mark of a lumber grading or inspec- tion agency which has been approved by an accreditation body that complies ...
Page 85
... grade mark , a certificate of inspection issued by a lumber grading or inspection agency meeting the requirements of ... grade lumber . Subflooring may be a minimum of utility grade lumber or No. 4 common grade boards . R502.1.3 End ...
... grade mark , a certificate of inspection issued by a lumber grading or inspection agency meeting the requirements of ... grade lumber . Subflooring may be a minimum of utility grade lumber or No. 4 common grade boards . R502.1.3 End ...
Page 111
... grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with DOC PS 20. In lieu of a grade mark , a certification of inspection issued by a lumber grading or inspection agency ...
... grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with DOC PS 20. In lieu of a grade mark , a certification of inspection issued by a lumber grading or inspection agency ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength