International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 76
Page 11
... heating and / or cooling systems or appliances capa- ble of maintaining , through design or heat loss / gain , 68 ° F ( 20 ° C ) during the heating season and / or 80 ° F ( 27 ° C ) during the cooling season , or has a fixed opening ...
... heating and / or cooling systems or appliances capa- ble of maintaining , through design or heat loss / gain , 68 ° F ( 20 ° C ) during the heating season and / or 80 ° F ( 27 ° C ) during the cooling season , or has a fixed opening ...
Page 290
... heat gain coefficient for fenestra- tion products . The area - weighted - average solar heat gain co- efficient ( SHGC ) for glazed fenestration installed in locations with 3,500 or fewer heating degree days shall not exceed 0.40 ...
... heat gain coefficient for fenestra- tion products . The area - weighted - average solar heat gain co- efficient ( SHGC ) for glazed fenestration installed in locations with 3,500 or fewer heating degree days shall not exceed 0.40 ...
Page 331
... heating or cool- ing , hot water heating , and swimming pool heating . M2301.2 Installation . Installation of solar energy systems shall comply with Sections M2301.2.1 through M2301.2.9 . M2301.2.1 Access . Solar energy collectors ...
... heating or cool- ing , hot water heating , and swimming pool heating . M2301.2 Installation . Installation of solar energy systems shall comply with Sections M2301.2.1 through M2301.2.9 . M2301.2.1 Access . Solar energy collectors ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength