International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 82
Page 184
... LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN - GRID ICF WALLS ( WIND PERPENDICULAR TO RIDGE ) a , b , c WIND VELOCITY PRESSURE FROM TABLE R611.7.4 WALL CATEGORY BUILDING SIDE WALL LENGTH , L ( feet ) 20 25 30 35 40 45 50 60 ROOF SLOPE ...
... LENGTH REQUIREMENTS FOR WAFFLE AND SCREEN - GRID ICF WALLS ( WIND PERPENDICULAR TO RIDGE ) a , b , c WIND VELOCITY PRESSURE FROM TABLE R611.7.4 WALL CATEGORY BUILDING SIDE WALL LENGTH , L ( feet ) 20 25 30 35 40 45 50 60 ROOF SLOPE ...
Page 305
... length and shall be listed and la- beled in accordance with UL 2158A . Transition ducts shall not be concealed ... Length limitation . The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet ( 7620 mm ) from the dryer ...
... length and shall be listed and la- beled in accordance with UL 2158A . Transition ducts shall not be concealed ... Length limitation . The maximum length of a clothes dryer exhaust duct shall not exceed 25 feet ( 7620 mm ) from the dryer ...
Page 538
... Length Method ) . The gas to be used has 0.60 specific gravity and a heating value of 1,000 Btu / ft3 ( 37.5 MJ / m3 ) . Solution ( 1 ) Section A ( a ) The length of tubing from the point of delivery to the most remote appliance is 50 ...
... Length Method ) . The gas to be used has 0.60 specific gravity and a heating value of 1,000 Btu / ft3 ( 37.5 MJ / m3 ) . Solution ( 1 ) Section A ( a ) The length of tubing from the point of delivery to the most remote appliance is 50 ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength