International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 83
Page 124
... Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method 3 and 25 % of braced wall line for Methods 2 , 4 , 5 , 6 , 7 or 8 . Minimum 48 - inch - wide panels located at each end and ...
... Located at each end and at least every 25 feet on center but not less than 16 % of braced wall line for Method 3 and 25 % of braced wall line for Methods 2 , 4 , 5 , 6 , 7 or 8 . Minimum 48 - inch - wide panels located at each end and ...
Page 368
... located at least 12 inches ( 305 mm ) above grade . 3. The vent terminal of a direct - vent appliance with an input . of 10,000 Btu per hour ( 3 kW ) or less shall be located at least 6 inches ( 152 mm ) from any air opening into a ...
... located at least 12 inches ( 305 mm ) above grade . 3. The vent terminal of a direct - vent appliance with an input . of 10,000 Btu per hour ( 3 kW ) or less shall be located at least 6 inches ( 152 mm ) from any air opening into a ...
Page 501
... located , shall be single and of the locking and grounding type and shall be protected by ground - fault cir- cuit interrupters . Other receptacles on the property shall be located not less than 10 feet ( 3048 m ) from the inside walls ...
... located , shall be single and of the locking and grounding type and shall be protected by ground - fault cir- cuit interrupters . Other receptacles on the property shall be located not less than 10 feet ( 3048 m ) from the inside walls ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength