International Residential Code for One- and Two-family DwellingsThe 2003 International Residential Code brings uniformity to construction of one- and two-family dwellings and townhouses up to three stories high. A comprehensive code for homebuilding, this book brings together all building, plumbing, mechanical, and electrical provisions for one- and two-family residences. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of new materials and building designs. This 2003 edition is fully compatible with all the International Codes published by the International Code Council (ICC). |
From inside the book
Results 1-3 of 30
Page 471
... RECEPTACLE OUTLETS E3801.1 General . Receptacle outlets shall be provided in ac- cordance with Sections E3801.2 through E3801.11 . Receptacle outlets required by this section shall be in addition to any recep- tacle that is part of a ...
... RECEPTACLE OUTLETS E3801.1 General . Receptacle outlets shall be provided in ac- cordance with Sections E3801.2 through E3801.11 . Receptacle outlets required by this section shall be in addition to any recep- tacle that is part of a ...
Page 472
... RECEPTACLES GFCI SINK GFCI GFCI GFCI E3801.4.1 Wall counter space . A receptacle outlet shall be installed at each wall counter space 12 inches ( 305 mm ) or wider . Receptacle outlets shall be installed so that no point along the wall ...
... RECEPTACLES GFCI SINK GFCI GFCI GFCI E3801.4.1 Wall counter space . A receptacle outlet shall be installed at each wall counter space 12 inches ( 305 mm ) or wider . Receptacle outlets shall be installed so that no point along the wall ...
Page 494
... receptacles . Receptacles rated at 20 am- peres or less and directly connected to aluminum conductors shall be marked CO / ALR . E3902.4 Faceplates . Metal face plates shall be grounded . E3902.5 Position of receptacle faces . After ...
... receptacles . Receptacles rated at 20 am- peres or less and directly connected to aluminum conductors shall be marked CO / ALR . E3902.4 Faceplates . Metal face plates shall be grounded . E3902.5 Position of receptacle faces . After ...
Contents
AE502 Foundation Systems | 61 |
Part IIIBuilding Planning and Construction 21 | 86 |
E3703 Underground Installation Requirements | 468 |
Copyright | |
3 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table ampacity appliance applied approved ASTM bonding jumper braced wall line ceiling joists clearance clothes dryer combustion air comply concrete conductors connected construction dead load Design Required diameter draft hood ducts equipment exceed FAN NAT FAN fastened feet fireplace fixture floor flue foundation walls furnace grade Ground snow load grounding conductor grout heaters heating height horizontal ICF wall installed in accordance insulating concrete form insulation joints kN/m² less LINTEL listed and labeled load-bearing located manufacturer's installation instructions masonry heater maximum metal minimum nail NAT FAN NAT opening outlet permitted piping material plate pound per square pressure R-value rafter spans reinforcement roof screws Seismic Design Category sheathing slope snow load psf Southern pine space square foot studs thickness tion Type underlayment units valve vent connector venting system vertical wall studs Wood shingles wood structural panel yield strength