Page 3-252
... approved auto- matic sprinkler system , lateral piping to 2 / 2 - in . ( 63.5 - mm ) hose connections shall not be required to be protected . Exception No. 2 : Piping connecting standpipes to 1 / 2 - in . ( 38.1 - mm ) hose connections ...
... approved auto- matic sprinkler system , lateral piping to 2 / 2 - in . ( 63.5 - mm ) hose connections shall not be required to be protected . Exception No. 2 : Piping connecting standpipes to 1 / 2 - in . ( 38.1 - mm ) hose connections ...
Page 3-256
... approved water supply capable of supplying the system demand . Manual standpipe systems shall have an approved water supply accessible to a fire department pumper . A single automatic or semiautomatic water supply shall be acceptable ...
... approved water supply capable of supplying the system demand . Manual standpipe systems shall have an approved water supply accessible to a fire department pumper . A single automatic or semiautomatic water supply shall be acceptable ...
Page 3-333
... approved national standards . 2. Sec . 1.2.3 is amended to read as follows : 1.2.3 . All references to the need for approval shall be inter- preted to mean approval by the building official . 3. Sec . 1.2.4 is amended to read as follows ...
... approved national standards . 2. Sec . 1.2.3 is amended to read as follows : 1.2.3 . All references to the need for approval shall be inter- preted to mean approval by the building official . 3. Sec . 1.2.4 is amended to read as follows ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood