Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 62
Page 3-14
... classification on the basis of the temperature criteria specified in Section 7.128 , Item 3 , for assembly classifications up to and including one hour . For classifications greater than one hour , the above temperature criteria shall ...
... classification on the basis of the temperature criteria specified in Section 7.128 , Item 3 , for assembly classifications up to and including one hour . For classifications greater than one hour , the above temperature criteria shall ...
Page 3-15
... classification of a restrained beam may be obtained by this procedure and based upon the conditions of acceptance specified in Section 7.133 . The fire - endurance classification so derived shall be applicable to the beam when used with ...
... classification of a restrained beam may be obtained by this procedure and based upon the conditions of acceptance specified in Section 7.133 . The fire - endurance classification so derived shall be applicable to the beam when used with ...
Page 3-328
... classified as GW - GM rather than GW - GC . ) SECTION 18.107 - - PROCEDURE FOR CLASSIFICATION OF FINE - GRAINED SOILS ( 50 PERCENT OR MORE PASSING ) From the material passing the 3 - inch ( 76 mm ) sieve , select a test sample for the ...
... classified as GW - GM rather than GW - GC . ) SECTION 18.107 - - PROCEDURE FOR CLASSIFICATION OF FINE - GRAINED SOILS ( 50 PERCENT OR MORE PASSING ) From the material passing the 3 - inch ( 76 mm ) sieve , select a test sample for the ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood